Get a Quote

Consilium Salwico ST450EC Fixed Electrochemical Gas Detector

Brand: Consilium Salwico ● In Stock & Ready for Dispatch
Consilium Salwico ST450EC fixed electrochemical gas detector with LCD display installed onboard a marine vessel for continuous toxic and oxygen gas monitoring.
The Consilium Salwico ST450EC Fixed Electrochemical Gas Detector provides continuous monitoring of oxygen and toxic gases with advanced diagnostics, LCD display, and dual communication for marine and offshore safety applications.

The Consilium Salwico ST450EC Fixed Electrochemical Gas Detector is an advanced fixed gas detector designed for continuous monitoring of oxygen (O₂), toxic gases, and hydrogen (H₂) in marine, offshore, and industrial environments. Built for hazardous areas, the ST450EC features a replaceable electrochemical sensor, integrated graphic LCD display, capacitive touch-style controls, self-diagnostics, and both 4–20 mA analogue and RS485 Modbus RTU communication. It is certified for ATEX and IECEx hazardous locations, making it suitable for demanding marine safety applications.

Technical Specifications

SpecificationDetails
Product NameConsilium Salwico ST450EC Fixed Electrochemical Gas Detector
ManufacturerConsilium Safety Group (formerly BUVECO Gasdetection BV, a Consilium Group Company)
Detector TypeFixed Electrochemical Gas Detector
Detection PrincipleReplaceable Electrochemical Sensor (2- or 3-electrode)
Target GasesOxygen (O₂), Hydrogen Sulphide (H₂S), Carbon Monoxide (CO), Hydrogen (H₂)
Measuring RangesO₂: 0–25 Vol.%H₂S: 0–30, 0–50, or 0–100 ppmCO: 0–500 ppmH₂: 0–1000 ppm or 0–100% LEL
DisplayDigital graphic LCD with backlight
Status IndicationGreen: OK, Red: Alarm, Yellow: System Failure, Blue: User Menu Active
User InterfaceCapacitive touch keys for configuration and calibration (no magnetic tool required)
Power Supply17.5–24 VDC
Maximum Current ConsumptionUp to 120 mA
Analog Output4–20 mA (2 mA for system failure, >20 mA for over-range)
Digital CommunicationRS-485 Modbus RTU (Half-Duplex)
Load ImpedanceMaximum 300 Ω at 24 VDC
Signal Cable2-wire shielded cable, 0.75–2.5 mm²
Cable GlandM20 × 1.5, Brass (standard), Stainless Steel (optional)
Enclosure MaterialCoated Aluminium (standard) or Stainless Steel (optional)
Sensor HousingStainless Steel SS316
Ingress ProtectionIP66 (Enclosure), Sensor IP6X
Dimensions (H × W × D)179 × 189 × 107 mm
WeightAluminium: 1.8 kgStainless Steel: 3.15 kg
Pressure RangeToxic Gas Sensors: Atmospheric ±10%Oxygen Sensor: 80–120 kPa
Operating TemperatureDepends on gas type:• O₂: –20°C to +55°C• H₂S: –20°C to +50°C• CO: –20°C to +50°C• H₂: –20°C to +40°C
Relative HumidityTypically 5–95% RH (non-condensing), depending on sensor type
Explosion ProtectionATEX: II 2G Ex db IIC T6 Gb, II 2D Ex tb IIIC T85°C Db
IECEx ApprovalEx db IIC T6 Gb, Ex tb IIIC T85°C Db
StandardsEN 50104 (O₂), EN 45544-1/-3 (H₂S), EN 50270, EN 50271, EMC Directive 2014/30/EU
CalibrationZero and span calibration via built-in user menu
Self-DiagnosticsIntegrated sensor and system diagnostics
MountingWall-mounted
Compatible SystemsGS5000, SW2020, BUCONTROL, BUTOUCH Gas Detection Systems
Typical ApplicationsMarine vessels, Oil & Gas, Refineries, Water & Wastewater, Chemical Plants, Food Industry, Pharmaceutical Industry, Steel Plants, Laboratories, Hydrogen Applications

Frequently Asked Questions

What is the Consilium Salwico ST450EC Fixed Electrochemical Gas Detector?

The Consilium Salwico ST450EC Fixed Electrochemical Gas Detector is an advanced fixed gas detector designed for continuous monitoring of oxygen and toxic gases in marine, offshore, and industrial environments. It features a replaceable electrochemical sensor, graphic LCD display, integrated diagnostics, and supports both 4–20 mA analogue and RS485 Modbus RTU communication.

Which gases can the ST450EC detect?

Depending on the installed sensor, the ST450EC can monitor:

  • Oxygen (O₂)
  • Hydrogen Sulphide (H₂S)
  • Carbon Monoxide (CO)
  • Hydrogen (H₂)

Different sensor cartridges are available for different applications.

What detection technology does the ST450EC use?

The ST450EC uses electrochemical sensing technology, which provides highly accurate and stable measurement of oxygen and toxic gas concentrations.

Where is the ST450EC commonly installed?

Typical installation locations include:

  • Engine Rooms
  • Cargo Pump Rooms
  • Compressor Rooms
  • Battery Rooms
  • Pump Stations
  • Cargo Holds
  • Ballast Tanks
  • Offshore Platforms
  • FPSOs
  • Refineries
  • Hazardous Process Areas
  • Confined Spaces
Which gas detection systems are compatible with the ST450EC?

The detector can be integrated with:

  • Consilium Salwico Gas Detection Systems
  • Marine Automation Systems
  • PLC-Based Safety Systems
  • SCADA Monitoring Systems

using 4–20 mA analogue output or RS485 Modbus RTU communication.

Does the ST450EC have a local display?

Yes.

The detector features an integrated graphic LCD display that shows:

  • Gas concentration
  • Detector status
  • Alarm condition
  • Fault messages
  • Calibration menus
  • Diagnostic information
Does the detector require calibration?

Yes.

Routine calibration is recommended to maintain measurement accuracy. Calibration intervals should follow the manufacturer's recommendations and the vessel's Planned Maintenance System (PMS).

What is a bump test?

A bump test exposes the detector to certified test gas to verify proper sensor response and alarm operation without performing a complete calibration.

What are the most common operational problems?

Typical issues include:

  • Sensor ageing
  • Calibration drift
  • Sensor contamination
  • Wiring faults
  • Communication errors
  • Power supply failure
  • End of sensor service life
  • Display or electronics faults

Routine maintenance significantly reduces these issues.

How often should the electrochemical sensor be replaced?

Sensor life depends on:

  • Gas type
  • Environmental conditions
  • Operating hours
  • Exposure to contaminants
  • Maintenance practices

Replacement is recommended when the sensor fails calibration, functional testing, or reaches its specified service life.

What spare parts are commonly available?

Common spare parts include:

  • Electrochemical Sensor Cartridges
  • LCD Display Modules
  • Detector Electronics
  • Calibration Adapters
  • Cable Glands
  • Dust Filters
  • Terminal Blocks
  • Mounting Brackets
  • Detector Covers
  • Communication Modules
  • Calibration Kits

Availability depends on the installed detector version.

Can the ST450EC be installed in hazardous areas?

Yes.

The ST450EC is designed for hazardous area installation and carries ATEX and IECEx certifications, making it suitable for use in marine and offshore environments where flammable gases or combustible dust may be present.

Why should genuine Consilium spare parts be used?

Using genuine Consilium components helps ensure:

  • Accurate gas detection
  • Reliable alarm performance
  • Long equipment life
  • Full system compatibility
  • Compliance with marine and hazardous area standards
How can I identify the correct replacement detector or sensor?

Provide the following information:

  • Model Number
  • Serial Number
  • Equipment Nameplate
  • Target Gas Type
  • Vessel Name
  • Existing Part Number (if available)

This helps ensure the correct detector or replacement sensor is supplied.

Who typically uses the ST450EC?

Typical users include:

  • Chief Engineers
  • Electrical Technical Officers (ETO)
  • Marine Engineers
  • Safety Officers
  • Cargo Officers
  • Technical Superintendents
  • Shipowners
  • Offshore Maintenance Engineers
  • Industrial Safety Engineers
  • Automation Engineers
Direct Marine Supply Desk

Need Consilium Salwico ST450EC Fixed Electrochemical Gas Detector or Spare Parts?

Get in touch with Ship Care Service for immediate commercial pricing, lead times, certificate verification, and Singapore anchorage launch delivery.

Fast 2–4h Technical Quotation 100% Genuine Certified Marine Gear Singapore Launch & Worldwide Dispatch
Chat with us on WhatsApp
Request a Quote