Overview
DECKMA OMD-24 Series 15ppm Bilge Alarm Unit | IMO Approved Marine Oil Content Monitor
The DECKMA OMD-24 Series 15ppm Bilge Alarm Unit is a marine oil content monitoring system designed to continuously measure the oil concentration in treated bilge water discharged from approved oily water separators. Developed for commercial vessels and offshore applications, the OMD-24 Series helps ship operators comply with MARPOL Annex I and IMO Resolution MEPC.107(49) by monitoring oil content, activating alarms, and controlling overboard discharge when permitted oil concentration limits are exceeded. The system combines a compact control unit, optical measuring cell, and built-in data logging to deliver dependable long-term performance in demanding marine environments.
At Ship Care Service, we supply genuine DECKMA OMD-24 Series 15ppm Bilge Alarm Units, measuring cells, spare parts, replacement accessories, and technical support for commercial vessels, offshore platforms, shipyards, and marine engineering companies worldwide.
What is the DECKMA OMD-24 Series?
The DECKMA OMD-24 Series is an IMO-approved 15ppm Bilge Alarm Unit installed downstream of an approved oily water separator. It continuously measures the oil concentration in treated bilge water before discharge overboard.
If the measured oil concentration exceeds the configured alarm level, the system activates visual and audible alarms and can automatically operate an Automatic Stopping Device (ASD) to prevent non-compliant discharge. The unit also records operational events and alarm history, supporting onboard maintenance and regulatory inspections.
Why a 15ppm Bilge Alarm is Important
International marine pollution regulations require ships equipped with oily water separators to continuously monitor discharged bilge water.
A certified bilge alarm helps operators:
Support compliance with MARPOL Annex I
Meet IMO MEPC.107(49) requirements
Prevent accidental oil discharge
Protect the marine environment
Assist during Port State Control inspections
Maintain discharge records
Improve onboard environmental compliance
How the DECKMA OMD-24 Series Works
The OMD-24 Series continuously monitors treated bilge water whenever the oily water separator is operating.
Step 1 – Bilge Water Sampling
A continuous sample of treated bilge water flows through the measuring cell installed after the oily water separator.
Step 2 – Optical Oil Content Measurement
The measuring cell continuously measures the oil concentration using an optical measurement principle, providing real-time monitoring of treated bilge water.
Step 3 – Signal Processing
The computer unit continuously evaluates:
Oil concentration
Alarm conditions
Measuring cell status
System health
Operational records
The graphic display provides operators with real-time operating information and alarm status.
Step 4 – Alarm & Automatic Discharge Control
If oil concentration exceeds the configured alarm level, the system can:
Activate visual alarms
Activate audible alarms
Operate the Automatic Stopping Device (ASD)
Stop or divert overboard discharge
Record alarm events through the integrated data logging system
This helps prevent overboard discharge that exceeds permitted oil concentration limits.
Key Features of the DECKMA OMD-24 Series
IMO Type Approved
The OMD-24 Series exceeds the performance requirements for 15ppm Bilge Alarms specified in IMO Resolution MEPC.107(49) when installed with approved oily water separator systems.
Adjustable Alarm Set Points
The unit is factory supplied with dual alarms set at 15 ppm, while alarm values from 1 ppm to 15 ppm can be adjusted on site to suit operational requirements.
Graphic Display
The integrated graphic display allows operators to monitor:
Oil concentration
Alarm status
System information
Operating parameters
Maintenance information
Integrated Data Logging
The OMD-24 Series records operational events and alarm history, providing valuable information for maintenance planning and regulatory inspections.
Optional Measuring Cell Cleaning Systems
Depending on the selected model, the OMD-24 Series can be supplied with:
Manual Cell Cleaning
Measuring Cell Cleaning Unit (MCU)
Automatic Cell Cleaning Device
Electric Switchover Valve
These options help reduce maintenance requirements while supporting consistent measurement performance.
Flexible Installation
The computer unit and measuring cell can be installed together or separately, making the OMD-24 Series suitable for new vessel construction and retrofit applications where installation space may be limited.
Typical Applications
The DECKMA OMD-24 Series is commonly installed on:
Container Ships
Bulk Carriers
Oil Tankers
Chemical Tankers
Offshore Support Vessels
Passenger Ships
Naval Vessels
General Cargo Ships
Marine Power Plants
Industries We Serve
The OMD-24 Series is widely used across:
Who Uses the DECKMA OMD-24 Series?
Typical users include:
Chief Engineers
Marine Engineers
Technical Superintendents
Shipowners
Ship Management Companies
Offshore Operators
Marine Service Engineers
Environmental Compliance Officers
Shipyards
Why Choose the DECKMA OMD-24 Series?
Marine operators worldwide choose the DECKMA OMD-24 Series because it offers:
Continuous 15ppm oil content monitoring
IMO MEPC.107(49) compliant performance
Adjustable alarm settings
Integrated data logging
Graphic display for easy operation
Flexible installation options
Optional automatic measuring cell cleaning
Reliable long-term operation in marine environments
Technical Overview
The DECKMA OMD-24 Series 15ppm Bilge Alarm Unit is a certified marine oil content monitoring system designed to continuously measure the oil concentration in treated bilge water discharged from approved oily water separator systems. Installed downstream of the separator, the OMD-24 Series continuously monitors oil content before overboard discharge, helping vessels comply with MARPOL Annex I and IMO Resolution MEPC.107(49).
The system consists of a computer unit, an optical measuring cell, and associated sampling and communication components. During operation, treated bilge water flows through the measuring cell where oil concentration is continuously measured. The computer unit processes the measured values, supervises the complete monitoring system, records operational events, and activates alarms or automatic stopping devices whenever oil concentration exceeds the configured discharge limit.
Its modular design, integrated event recording, adjustable alarm settings, and optional automatic measuring cell cleaning make the OMD-24 Series suitable for commercial vessels, offshore installations, and retrofit projects.
Note: System configuration, communication interfaces, optional accessories, and installation arrangements may vary depending on vessel design and oily water separator manufacturer. Always verify equipment details using the equipment nameplate and official DECKMA documentation.
Main Components of the OMD-24 Series
The DECKMA OMD-24 Series consists of several integrated components designed for continuous oil content monitoring.
Computer Unit
The computer unit serves as the central operating and monitoring interface.
Its functions include:
The graphic display provides operators with real-time operating information and alarm status.
Optical Measuring Cell
The measuring cell continuously analyzes treated bilge water flowing from the oily water separator.
Its functions include:
Optical oil content measurement
Continuous sampling
Stable long-term monitoring
High measurement reliability
Depending on the system configuration, optional automatic cleaning devices are available to simplify maintenance.
Sampling System
The sampling arrangement directs treated bilge water through the measuring cell to ensure continuous oil concentration monitoring during separator operation.
Automatic Stopping Device (ASD) Interface
When oil concentration exceeds the configured alarm value, the OMD-24 Series can activate an Automatic Stopping Device to stop or divert overboard discharge.
Data Logging System
The integrated memory records important operational information including:
Alarm history
Operational events
System status
Maintenance records
This information supports onboard maintenance and inspection requirements.
Working Principle
The DECKMA OMD-24 Series continuously monitors treated bilge water whenever the oily water separator is operating.
Step 1 – Continuous Bilge Water Sampling
A representative sample of treated bilge water flows continuously through the measuring cell.
Step 2 – Optical Oil Content Measurement
The measuring cell continuously measures oil concentration using an optical sensing principle.
The detector evaluates changes in oil concentration while maintaining stable measurement performance.
Step 3 – Digital Signal Processing
The computer unit continuously processes measured values while supervising:
Oil concentration
Measuring cell status
Alarm conditions
System health
Operational records
Step 4 – Alarm & Automatic Discharge Protection
When oil concentration exceeds the configured alarm threshold, the system can:
Activate visual alarms
Activate audible alarms
Operate the Automatic Stopping Device
Stop or divert overboard discharge
Record alarm events for maintenance and inspection purposes
This helps prevent non-compliant discharge of oily water into the marine environment.
Advantages of the DECKMA OMD-24 Series
Continuous Oil Content Monitoring
The OMD-24 Series continuously supervises treated bilge water throughout separator operation.
Regulatory Compliance
The system supports compliance with international marine pollution prevention regulations for oily water discharge.
Flexible Installation
The modular design allows installation on both new vessels and retrofit projects with varying machinery layouts.
Adjustable Alarm Settings
Alarm values can be configured within the allowable operating range to suit vessel requirements while maintaining regulatory compliance.
Integrated Event Recording
Built-in event logging provides valuable operational history for maintenance planning and inspections.
Optional Automatic Measuring Cell Cleaning
Optional measuring cell cleaning systems help reduce contamination and simplify routine maintenance.
Marine-Grade Construction
Designed specifically for marine environments, the OMD-24 Series operates reliably under:
Routine Maintenance
Routine maintenance helps ensure accurate oil content measurement and reliable long-term operation.
Before Operation
Inspect:
Computer unit display
Alarm indicators
Measuring cell condition
Sampling lines
Electrical connections
Verify that the system indicates normal operating condition before operating the oily water separator.
Weekly Inspection
Check:
Inspect the sampling arrangement for contamination or blockage.
Monthly Inspection
Inspect:
Measuring cell
Sampling system
Optional cleaning device
Electrical wiring
Connectors
Mounting hardware
Clean the measuring cell according to the manufacturer's maintenance recommendations where required.
Annual Maintenance
Recommended maintenance includes:
Functional testing
Measuring cell inspection
Calibration verification
Alarm testing
Data logging verification
Electrical inspection
Sampling system inspection
Maintenance activities should be documented within the vessel's Planned Maintenance System (PMS).
Common Operational Problems
Although the OMD-24 Series is designed for dependable long-term service, certain operational issues may occasionally occur.
Problem: High Oil Content Alarm
Possible Causes
Oily water separator malfunction
Excessive oil contamination
Dirty measuring cell
Incorrect separator operation
Recommended Solution
Inspect the oily water separator, verify system performance, and clean the measuring cell if necessary.
Problem: Measuring Cell Contamination
Possible Causes
Oil deposits
Sludge accumulation
Insufficient cleaning
Dirty sampling lines
Recommended Solution
Inspect and clean the measuring cell according to DECKMA maintenance procedures.
Problem: No Sample Flow
Possible Causes
Recommended Solution
Inspect the sampling arrangement and restore proper sample flow before resuming operation.
Problem: Display or Communication Fault
Possible Causes
Recommended Solution
Verify the electrical supply, inspect communication wiring, and confirm correct control unit operation.
Problem: Frequent False Alarms
Possible Causes
Recommended Solution
Inspect the measuring cell, verify sample flow stability, and perform calibration verification where required.
Calibration Recommendations
To maintain accurate oil content measurement, periodic calibration verification should be carried out according to DECKMA maintenance procedures and the vessel's Planned Maintenance System.
Calibration is generally recommended:
During scheduled maintenance
After replacing the measuring cell
Following major servicing
After extended shutdown
According to manufacturer recommendations
As required by company maintenance procedures
Genuine Spare Parts Available
Ship Care Service supplies genuine replacement parts for the DECKMA OMD-24 Series, including:
Availability depends on the installed system configuration.
Buying Guide
Before purchasing an OMD-24 Series unit or replacement components, consider the following:
Verify System Compatibility
Confirm compatibility with the installed oily water separator and vessel configuration.
Confirm Equipment Identification
Providing the following information helps identify compatible replacement components:
Choose Genuine Components
Using genuine replacement parts helps maintain:
Accurate oil content monitoring
Reliable alarm operation
Long equipment service life
Proper regulatory compliance
Full compatibility with the installed system
Work with an Experienced Marine Supplier
Choose a supplier capable of providing:
Genuine DECKMA products
Technical assistance
Spare parts support
Worldwide marine supply
After-sales service
Why Marine Operators Choose the DECKMA OMD-24 Series
The DECKMA OMD-24 Series 15ppm Bilge Alarm Unit is trusted because it offers:
Continuous oil content monitoring
IMO-compliant operation
Adjustable alarm settings
Integrated event recording
Flexible installation
Optional automatic measuring cell cleaning
Easy maintenance