Overview
DECKMA OMD-2008 EV FC MCU | 15ppm Bilge Alarm with Flow Control & Manual Cleaning Unit
The DECKMA OMD-2008 EV FC MCU is an advanced version of the OMD-2008 15ppm Bilge Alarm, designed for continuous monitoring of oil content in treated bilge water discharged from approved oily water separator systems. It incorporates an Electric Valve (EV), Flow Control (FC), and a Manual Cleaning Unit (MCU) to improve operational reliability, simplify maintenance, and help prevent unlawful overboard discharge caused by insufficient sample flow. The system supports compliance with MARPOL Annex I and IMO Resolution MEPC.107(49) for marine pollution prevention.
At Ship Care Service, we supply genuine DECKMA OMD-2008 EV FC MCU systems, measuring cells, flow sensors, electric valves, spare parts, accessories, calibration support, and technical assistance for commercial vessels, offshore platforms, shipyards, and marine engineering companies worldwide.
What is the DECKMA OMD-2008 EV FC MCU?
The DECKMA OMD-2008 EV FC MCU is a marine 15ppm Bilge Alarm Unit installed downstream of an approved oily water separator. In addition to continuous oil content monitoring, this model includes three enhanced functions:
EV (Electric Valve) – Automatically controls the clean water flushing process.
FC (Flow Control) – Monitors sample flow and places the instrument into alarm if adequate sample flow is not maintained.
MCU (Manual Cleaning Unit) – Allows the measuring tube to be cleaned quickly without opening the measuring cell, reducing maintenance time.
These features help improve system reliability while reducing the possibility of incorrect measurements caused by interrupted or insufficient sample flow.
Why a Bilge Alarm with Flow Control is Important
Accurate oil content measurement depends on maintaining a continuous representative sample through the measuring cell.
The integrated Flow Control (FC) system continuously checks the sample flow. If flow becomes too low or stops completely, the instrument generates a "Flow?" status alarm, preventing operation with an invalid sample and reducing the risk of accidental non-compliant discharge.
This provides additional protection for:
Environmental compliance
Safe vessel operation
Accurate oil content monitoring
Port State Control inspections
Oily water separator performance verification
How the DECKMA OMD-2008 EV FC MCU Works
The system continuously monitors treated bilge water during oily water separator operation.
Step 1 – Bilge Water Sampling
A representative sample of treated bilge water flows through the optical measuring cell.
Step 2 – Optical Oil Content Measurement
The measuring cell continuously measures oil concentration using DECKMA's optical sensing technology, providing real-time monitoring of treated bilge water.
Step 3 – Flow Control Monitoring
The integrated flow sensor continuously monitors sample flow through the measuring cell.
If sufficient sample flow is not maintained, the system automatically enters alarm status and displays a Flow warning, helping ensure only valid measurements are used.
Step 4 – Alarm & Automatic Discharge Protection
When oil concentration exceeds the configured alarm value or an insufficient sample flow condition is detected, the system can:
Activate visual alarms
Activate audible alarms
Operate the Automatic Stopping Device (ASD)
Stop or divert overboard discharge
Record alarm events for future inspection
Key Features of the DECKMA OMD-2008 EV FC MCU
Integrated Flow Control (FC)
Unlike standard bilge alarms, the Flow Control version continuously supervises sample flow to help prevent inaccurate measurements caused by interrupted or insufficient flow.
Electric Valve (EV)
The integrated Electric Valve automatically manages sample water and clean water flushing, improving measurement reliability while simplifying operation.
Manual Cleaning Unit (MCU)
The optional Manual Cleaning Unit allows operators to clean the measuring glass tube without dismantling the measuring cell or interrupting sample flow, significantly reducing maintenance time.
Graphic Display
The integrated graphic display provides operators with convenient access to:
Oil concentration
Alarm status
Flow status
System diagnostics
Operating parameters
Maintenance information
Adjustable Alarm Settings
Alarm set points can be adjusted between 1 ppm and 15 ppm, with the factory setting at 15 ppm, allowing flexibility while supporting regulatory compliance.
Integrated Data Logging
The OMD-2008 EV FC MCU records operational events and alarm history, supporting onboard maintenance and environmental inspections.
Typical Applications
The DECKMA OMD-2008 EV FC MCU is commonly installed on:
Container Ships
Bulk Carriers
Oil Tankers
Chemical Tankers
Offshore Support Vessels
Passenger Ships
Naval Vessels
General Cargo Ships
Marine Power Plants
Industries We Serve
The OMD-2008 EV FC MCU is widely used across:
Who Uses the DECKMA OMD-2008 EV FC MCU?
Typical users include:
Chief Engineers
Marine Engineers
Technical Superintendents
Shipowners
Ship Management Companies
Offshore Operators
Marine Service Engineers
Environmental Compliance Officers
Shipyards
Why Choose the DECKMA OMD-2008 EV FC MCU?
Marine operators worldwide choose the DECKMA OMD-2008 EV FC MCU because it offers:
Continuous 15ppm oil content monitoring
Integrated Flow Control for improved measurement reliability
Automatic Electric Valve operation
Manual Cleaning Unit for simplified maintenance
Adjustable alarm settings
Graphic display with diagnostic functions
Integrated data logging
Compliance with IMO MEPC.107(49) requirements when used with approved oily water separator systems.
DECKMA OMD-2008 EV FC MCU – Technical Information, Operation, Maintenance & Troubleshooting
Technical Overview
The DECKMA OMD-2008 EV FC MCU is an advanced 15ppm Bilge Alarm Unit designed for continuous monitoring of oil concentration in treated bilge water discharged from approved oily water separator systems. This model combines the proven OMD-2008 oil content monitoring system with three additional functions: Electric Valve (EV), Flow Control (FC), and a Manual Cleaning Unit (MCU) to improve operational reliability, simplify maintenance, and enhance measurement accuracy.
Installed downstream of the oily water separator, the system continuously measures oil concentration before overboard discharge. The integrated Flow Control verifies that a sufficient sample flow is maintained, while the Electric Valve manages flushing operations and the Manual Cleaning Unit allows quick cleaning of the measuring tube without dismantling the measuring cell.
The system helps support compliance with MARPOL Annex I and IMO Resolution MEPC.107(49) when installed with an approved oily water separator.
Note: System configuration, electrical interfaces, cleaning arrangements, and installation details may vary depending on vessel design and oily water separator manufacturer. Always verify equipment information using the manufacturer's documentation and equipment nameplate.
Main Components of the OMD-2008 EV FC MCU
The DECKMA OMD-2008 EV FC MCU consists of several integrated components designed for continuous oil content monitoring.
Computer Unit
The computer unit functions as the central operating and monitoring interface.
Its primary functions include:
The graphic display provides real-time operating information and alarm status.
Optical Measuring Cell
The measuring cell continuously measures the oil concentration in treated bilge water.
Its functions include:
Optical oil content measurement
Continuous sample analysis
Stable long-term monitoring
Reliable measurement performance
The measuring tube can be cleaned using the integrated Manual Cleaning Unit.
Flow Control System (FC)
The Flow Control system continuously supervises sample flow through the measuring cell.
Its functions include:
Sample flow monitoring
Flow fault detection
Flow alarm generation
Measurement protection
If adequate sample flow is not detected, the system generates a flow alarm to prevent unreliable measurements.
Electric Valve (EV)
The Electric Valve automatically controls flushing and sample water flow.
Its functions include:
Automatic flushing control
Sample switching
Improved measuring cell cleaning
Reduced operator intervention
Manual Cleaning Unit (MCU)
The Manual Cleaning Unit enables cleaning of the measuring tube without dismantling the measuring cell.
Benefits include:
Data Logging System
The integrated memory records:
Alarm history
Operational events
System status
Maintenance information
These records support onboard maintenance and regulatory inspections.
Working Principle
The DECKMA OMD-2008 EV FC MCU continuously monitors treated bilge water whenever the oily water separator is operating.
Step 1 – Continuous Bilge Water Sampling
A representative sample of treated bilge water flows continuously through the optical measuring cell.
Step 2 – Optical Oil Content Measurement
The measuring cell continuously measures oil concentration using an optical sensing principle.
The detector evaluates changes in oil concentration while maintaining stable measurement performance.
Step 3 – Sample Flow Verification
The integrated Flow Control system continuously verifies that sufficient sample flow is maintained.
If sample flow becomes insufficient, the system activates a flow alarm and alerts the operator.
Step 4 – Alarm & Automatic Discharge Protection
When oil concentration exceeds the configured alarm level or an insufficient sample flow condition is detected, the system can:
Activate visual alarms
Activate audible alarms
Operate the Automatic Stopping Device
Stop or divert overboard discharge
Record alarm events for future review
Advantages of the DECKMA OMD-2008 EV FC MCU
Continuous Oil Content Monitoring
The system continuously monitors treated bilge water throughout separator operation.
Integrated Flow Monitoring
The Flow Control system improves measurement reliability by ensuring a valid sample is always available.
Simplified Maintenance
The Manual Cleaning Unit allows routine cleaning without dismantling the measuring cell.
Automatic Flushing
The Electric Valve automates flushing operations, reducing manual intervention and supporting consistent performance.
Adjustable Alarm Settings
Alarm values can be configured to meet vessel operational requirements while supporting regulatory compliance.
Integrated Event Recording
Built-in data logging provides valuable historical information for maintenance planning and inspections.
Marine-Grade Construction
The OMD-2008 EV FC MCU is designed for dependable operation in demanding marine environments, including:
Routine Maintenance
Routine maintenance helps maintain accurate oil content monitoring and reliable long-term operation.
Before Operation
Inspect:
Computer unit display
Alarm indicators
Measuring cell condition
Sample flow
Electrical connections
Confirm that the system indicates normal operating status before starting the oily water separator.
Weekly Inspection
Check:
Inspect for contamination or sample flow restrictions.
Monthly Inspection
Inspect:
Measuring cell
Manual Cleaning Unit
Electric Valve
Flow Control components
Electrical wiring
Connectors
Mounting hardware
Clean the measuring tube using the Manual Cleaning Unit when required.
Annual Maintenance
Recommended maintenance includes:
Functional testing
Calibration verification
Alarm testing
Flow Control testing
Electric Valve inspection
Measuring cell inspection
Data logging verification
Electrical inspection
Maintenance activities should be recorded in the vessel's Planned Maintenance System (PMS).
Common Operational Problems
Although the OMD-2008 EV FC MCU is designed for reliable long-term operation, certain operational issues may occasionally occur.
Problem: High Oil Content Alarm
Possible Causes
Oily water separator malfunction
Excessive oil contamination
Dirty measuring tube
Incorrect separator operation
Recommended Solution
Inspect the separator, verify oil content, and clean the measuring tube if required.
Problem: Flow Alarm
Possible Causes
Recommended Solution
Inspect the sampling arrangement and restore proper sample flow before resuming operation.
Problem: Measuring Tube Contamination
Possible Causes
Oil deposits
Sludge accumulation
Inadequate cleaning
Recommended Solution
Use the Manual Cleaning Unit to clean the measuring tube according to DECKMA maintenance procedures.
Problem: Electric Valve Malfunction
Possible Causes
Electrical fault
Valve obstruction
Wiring problem
Internal valve failure
Recommended Solution
Inspect the electrical supply, valve operation, and associated wiring before replacing components.
Problem: Display or Communication Fault
Possible Causes
Recommended Solution
Verify electrical connections and inspect the control unit.
Calibration Recommendations
Periodic calibration verification helps maintain accurate oil content measurement.
Calibration is generally recommended:
During scheduled maintenance
After replacing the measuring cell
Following major servicing
After extended shutdown
According to DECKMA maintenance procedures
As required by the vessel's Planned Maintenance System
Genuine Spare Parts Available
Ship Care Service supplies genuine replacement parts for the DECKMA OMD-2008 EV FC MCU, including:
Optical Measuring Cells
Computer Units
Flow Control Sensors
Electric Valves
Manual Cleaning Units
Measuring Tubes
Display Modules
Solenoid Valves
Power Supply Modules
Wiring Harnesses
Connectors
Mounting Hardware
Replacement Accessories
Availability depends on the installed system configuration.
Buying Guide
Before purchasing an OMD-2008 EV FC MCU or replacement components, consider the following:
Verify System Compatibility
Confirm compatibility with the installed oily water separator and vessel configuration.
Confirm Equipment Identification
Providing the following information helps identify compatible replacement components:
Choose Genuine Components
Using genuine replacement parts helps maintain:
Accurate oil content monitoring
Reliable Flow Control operation
Proper Electric Valve performance
Long equipment service life
Full regulatory compliance
System compatibility
Work with an Experienced Marine Supplier
Choose a supplier capable of providing:
Genuine DECKMA products
Technical assistance
Spare parts support
Worldwide marine supply
After-sales service
Why Marine Operators Choose the DECKMA OMD-2008 EV FC MCU
The DECKMA OMD-2008 EV FC MCU is trusted because it offers:
Continuous oil content monitoring
Integrated Flow Control
Automatic Electric Valve operation
Manual Cleaning Unit
Adjustable alarm settings
Built-in event recording
Easy maintenance
Reliable long-term marine performance