Overview
DECKMA OMD-2008 Series 15ppm Bilge Alarm Unit | IMO Approved Marine Oil Content Monitoring System
The DECKMA OMD-2008 Series 15ppm Bilge Alarm Unit is a marine oil content monitoring system designed for continuous measurement of oil concentration in treated bilge water discharged from approved oily water separator systems. Developed for commercial ships and offshore applications, the OMD-2008 Series exceeds the performance requirements of IMO Resolution MEPC.107(49) and supports compliance with MARPOL Annex I by continuously monitoring oil content, activating alarms, and controlling overboard discharge when preset limits are exceeded. The system combines a rugged measuring cell, intelligent computer unit, integrated data logging, and flexible alarm configuration to deliver reliable long-term performance in demanding marine environments.
At Ship Care Service, we supply genuine DECKMA OMD-2008 Series 15ppm Bilge Alarm Units, measuring cells, spare parts, replacement accessories, calibration support, and technical assistance for commercial vessels, offshore platforms, shipyards, and marine engineering companies worldwide.
What is the DECKMA OMD-2008 Series?
The DECKMA OMD-2008 Series is an IMO-approved 15ppm Bilge Alarm Unit installed downstream of an approved oily water separator. Its primary purpose is to continuously monitor the oil concentration in treated bilge water before discharge overboard.
If the measured oil concentration exceeds the configured alarm value, the system activates visual and audible alarms while operating the Automatic Stopping Device (ASD) when connected. The unit also records separator status, alarms, and operational events through its integrated data logging system.
Why a 15ppm Bilge Alarm is Important
International marine pollution regulations require vessels fitted with oily water separators to continuously monitor discharged bilge water.
A certified bilge alarm helps operators:
Support compliance with MARPOL Annex I
Meet IMO MEPC.107(49) requirements
Prevent accidental oil discharge
Protect the marine environment
Support Port State Control inspections
Maintain discharge records
Improve onboard environmental compliance
How the DECKMA OMD-2008 Series Works
The OMD-2008 Series continuously monitors treated bilge water whenever the oily water separator is operating.
Step 1 – Bilge Water Sampling
A representative sample of treated bilge water flows through the optical measuring cell installed after the oily water separator.
Step 2 – Optical Oil Content Measurement
The measuring cell continuously measures oil concentration using DECKMA's optical sensing technology. The microprocessor processes the sensor signals to provide accurate real-time oil content measurement.
Step 3 – Digital Signal Processing
The computer unit continuously evaluates:
The graphic display provides operators with real-time operating information.
Step 4 – Alarm & Automatic Discharge Control
When oil concentration exceeds the configured alarm value, the system can:
Activate visual alarms
Activate audible alarms
Operate the Automatic Stopping Device (ASD)
Stop or divert overboard discharge
Record operational events every 15 seconds as required for data logging.
Key Features of the DECKMA OMD-2008 Series
IMO Approved Performance
The OMD-2008 Series exceeds the performance requirements specified in IMO Resolution MEPC.107(49) for 15ppm Bilge Alarm Units.
Graphic LCD Display
The integrated graphic display provides easy access to:
Oil concentration
Alarm status
System diagnostics
Operating parameters
Maintenance information
Adjustable Alarm Settings
The unit is supplied with factory-adjusted alarms at 15 ppm, while alarm set points between 1 ppm and 15 ppm can be configured according to operational requirements. Optional 10 ppm and 5 ppm versions are also available.
Integrated Data Logging
The OMD-2008 Series continuously records:
Oil concentration
Alarm history
Separator status
Operating events
This information supports onboard maintenance and inspection requirements.
Flexible Installation
The system consists of a computer unit and measuring cell that can be installed for convenient operation and maintenance. It is suitable for both new vessel construction and retrofit applications.
Rugged Marine Construction
The measuring cell features an anodized aluminium body with stainless steel inlet and outlet components, designed for reliable operation in demanding marine environments.
Typical Applications
The DECKMA OMD-2008 Series is commonly installed on:
Container Ships
Bulk Carriers
Oil Tankers
Chemical Tankers
Offshore Support Vessels
Passenger Ships
Naval Vessels
General Cargo Ships
Marine Power Plants
Industries We Serve
The OMD-2008 Series is widely used across:
Who Uses the DECKMA OMD-2008 Series?
Typical users include:
Chief Engineers
Marine Engineers
Technical Superintendents
Shipowners
Ship Management Companies
Offshore Operators
Marine Service Engineers
Environmental Compliance Officers
Shipyards
Why Choose the DECKMA OMD-2008 Series?
Marine operators worldwide choose the DECKMA OMD-2008 Series because it offers:
Continuous 15ppm oil content monitoring
IMO-compliant performance
Adjustable alarm settings
Integrated event and data logging
Graphic LCD display
Rugged marine construction
Flexible installation
Reliable long-term operation onboard commercial vessels.
Technical Overview
The DECKMA OMD-2008 Series 15ppm Bilge Alarm Unit is a marine-approved oil content monitoring system designed for continuous measurement of oil concentration in treated bilge water discharged from approved oily water separator systems. Installed downstream of the separator, the OMD-2008 Series continuously monitors oil content before overboard discharge to help vessels comply with MARPOL Annex I and IMO Resolution MEPC.107(49).
The system consists of a computer unit, an optical measuring cell, and associated sampling and communication components. During operation, treated bilge water passes through the measuring cell where oil concentration is continuously measured. The computer unit processes measurement data, supervises system performance, records operational events, and activates alarms or automatic stopping devices whenever oil concentration exceeds the configured discharge limit.
Designed specifically for marine applications, the OMD-2008 Series combines accurate measurement, integrated event logging, flexible installation, and dependable long-term operation.
Note: Installation arrangements, communication interfaces, and optional accessories may vary depending on vessel design and oily water separator manufacturer. Always verify equipment configuration using the equipment nameplate and official DECKMA documentation.
Main Components of the OMD-2008 Series
The DECKMA OMD-2008 Series consists of several integrated components that work together to provide continuous oil content monitoring.
Computer Unit
The computer unit serves as the central operating and monitoring interface.
Its functions include:
The graphic LCD display provides operators with real-time operating information and alarm status.
Optical Measuring Cell
The measuring cell continuously analyzes treated bilge water flowing from the oily water separator.
Its functions include:
Optical oil content measurement
Continuous sample monitoring
Stable long-term operation
Reliable measurement performance
The measuring cell is designed for easy inspection and routine maintenance.
Sampling System
The sampling arrangement continuously delivers treated bilge water through the measuring cell to ensure accurate oil concentration monitoring during separator operation.
Automatic Stopping Device (ASD) Interface
When oil concentration exceeds the configured alarm level, the OMD-2008 Series can activate an Automatic Stopping Device to stop or divert overboard discharge.
Data Logging System
The integrated memory continuously records:
These records assist with maintenance planning and regulatory inspections.
Working Principle
The DECKMA OMD-2008 Series continuously monitors treated bilge water whenever the oily water separator is operating.
Step 1 – Continuous Bilge Water Sampling
A representative sample of treated bilge water flows continuously through the optical measuring cell.
Step 2 – Optical Oil Content Measurement
The measuring cell continuously measures oil concentration using an optical sensing principle.
The detector identifies changes in oil concentration while maintaining stable measurement accuracy.
Step 3 – Digital Signal Processing
The computer unit continuously processes measured values while supervising:
Oil concentration
Alarm status
Measuring cell condition
System diagnostics
Operational records
Step 4 – Alarm & Automatic Discharge Protection
When oil concentration exceeds the configured alarm threshold, the system can:
Activate visual alarms
Activate audible alarms
Operate the Automatic Stopping Device
Stop or divert overboard discharge
Record alarm events within the internal data logging system
This helps prevent accidental discharge of oily water exceeding permitted limits.
Advantages of the DECKMA OMD-2008 Series
Continuous Oil Content Monitoring
The OMD-2008 Series continuously supervises treated bilge water during oily water separator operation.
Regulatory Compliance
The system supports compliance with international marine pollution prevention regulations for oily water discharge.
Graphic LCD Display
The display provides operators with clear operating information, alarm status, diagnostic messages, and maintenance indications.
Adjustable Alarm Configuration
Alarm settings can be configured within the allowable operating range to meet vessel operational requirements.
Integrated Data Logging
The internal memory stores operational history and alarm events for maintenance records and environmental inspections.
Flexible Installation
Its modular design allows installation on new vessels as well as retrofit projects with varying engine room layouts.
Marine-Grade Construction
The OMD-2008 Series is designed to operate reliably under demanding marine conditions, including:
Routine Maintenance
Routine maintenance helps ensure reliable monitoring accuracy and dependable long-term operation.
Before Operation
Inspect:
Computer unit display
Alarm indicators
Measuring cell condition
Sampling lines
Electrical connections
Verify that the system indicates normal operating status before starting the oily water separator.
Weekly Inspection
Check:
Inspect the sampling arrangement for contamination or restrictions.
Monthly Inspection
Inspect:
Measuring cell
Sampling system
Electrical wiring
Connectors
Mounting hardware
Clean the measuring cell in accordance with DECKMA maintenance recommendations.
Annual Maintenance
Recommended maintenance includes:
Functional testing
Calibration verification
Alarm testing
Measuring cell inspection
Data logging verification
Electrical inspection
Sampling system inspection
Maintenance activities should be documented within the vessel's Planned Maintenance System (PMS).
Common Operational Problems
Although the OMD-2008 Series is designed for reliable long-term operation, certain operational issues may occasionally occur.
Problem: High Oil Content Alarm
Possible Causes
Oily water separator malfunction
Excessive oil contamination
Contaminated measuring cell
Incorrect separator operation
Recommended Solution
Inspect the separator, verify oil concentration, and clean the measuring cell if necessary.
Problem: Measuring Cell Contamination
Possible Causes
Oil deposits
Sludge accumulation
Insufficient cleaning
Dirty sampling lines
Recommended Solution
Inspect and clean the measuring cell following DECKMA maintenance procedures.
Problem: No Sample Flow
Possible Causes
Recommended Solution
Inspect the sampling arrangement and restore proper flow before resuming operation.
Problem: Display or Communication Fault
Possible Causes
Recommended Solution
Verify electrical supply, inspect wiring, and confirm correct operation of the computer unit.
Problem: Frequent False Alarms
Possible Causes
Recommended Solution
Inspect the measuring cell, verify sampling conditions, and perform calibration verification where required.
Calibration Recommendations
To maintain accurate oil content measurement, periodic calibration verification should be performed according to DECKMA maintenance procedures and the vessel's Planned Maintenance System.
Calibration is generally recommended:
During scheduled maintenance
After replacing the measuring cell
Following major servicing
After extended shutdown
According to manufacturer recommendations
As required by company maintenance procedures
Genuine Spare Parts Available
Ship Care Service supplies genuine replacement parts for the DECKMA OMD-2008 Series, including:
Optical Measuring Cells
Computer Units
Display Modules
Sampling Components
Solenoid Valves
Measuring Tubes
Power Supply Modules
Wiring Harnesses
Connectors
Mounting Hardware
Replacement Accessories
Availability depends on the installed system configuration.
Buying Guide
Before purchasing an OMD-2008 Series unit or replacement components, consider the following:
Verify System Compatibility
Confirm compatibility with the installed oily water separator and vessel configuration.
Confirm Equipment Identification
Providing the following information helps identify compatible replacement components:
Choose Genuine Components
Using genuine replacement parts helps maintain:
Accurate oil content monitoring
Reliable alarm operation
Long equipment service life
Regulatory compliance
Full compatibility with the installed system
Work with an Experienced Marine Supplier
Choose a supplier capable of providing:
Genuine DECKMA products
Technical assistance
Spare parts support
Worldwide marine supply
After-sales service
Why Marine Operators Choose the DECKMA OMD-2008 Series
The DECKMA OMD-2008 Series 15ppm Bilge Alarm Unit is trusted because it offers:
Continuous oil content monitoring
IMO-compliant operation
Graphic LCD display
Adjustable alarm settings
Integrated event recording
Easy maintenance
Flexible installation
Reliable long-term marine performance