Get a Quote

Graviner MK5 Oil Mist Detector

Brand: Graviner ● In Stock & Ready for Dispatch
Graviner MK5 Oil Mist Detector for marine diesel engine crankcase oil mist monitoring and engine safety protection.
The Graviner MK5 Oil Mist Detector continuously monitors crankcase oil mist concentration to provide early warning of abnormal engine conditions and enhance marine engine safety.

Protecting marine diesel engines from crankcase explosions is one of the most important aspects of engine safety. Excessive oil mist generated by overheated bearings, lubrication failures, or abnormal friction can rapidly develop into hazardous conditions if not detected in time. The Graviner MK5 Oil Mist Detector was developed to continuously monitor crankcase oil mist density and provide early warning before serious engine damage occurs.

Technical Specifications

ParameterSpecification
Product NameOil Mist Detector (OMD)
ManufacturerKidde Fire Protection Services Ltd. (Graviner), UK
ModelGraviner Mark 5 (MK5)
ApplicationMarine diesel engine crankcase oil mist monitoring
PurposeEarly detection of excessive oil mist caused by bearing overheating and prevention of engine damage
Detection PrincipleOptical obscurity measurement using light source and photocell
Sampling MethodSequential crankcase oil mist sampling
Number of Sampling Inlets4 to 10 selectable sampling points
Sampling TimeApprox. 1 second per sample
Detection RangeAverage alarm level: 0.3 – 1.3 mg/L oil mist; Deviation alarm level: 0.05 – 0.5 mg/L oil mist
Maximum Distance Between Detector and Sample PointUp to 45 m (depending on pipe size)
Air Supply Pressure1 bar ±20% (12–18 psi)
Air ConsumptionApprox. 6 litres/hour
Power SupplySelectable: 115V AC / 220V AC / 230V AC / 240V AC, 50/60 Hz
Power ConsumptionApprox. 70 W
Display IndicationsSystem ON, % Alarm Level, Sample Number, Simulation Mode, Test Mode, Average Alarm, Deviation Alarm, Flow Fault, Optical Fault
Alarm OutputsFault Alarm, Main Alarm, Engine Slow Down Alarm
Fault Alarm Output1 set volt-free change-over contacts
Main Alarm Output2 sets volt-free change-over contacts
Engine Slow Down Output1 set volt-free change-over contacts
Remote FunctionsRemote TEST and RESET facility
Detector Dimensions (Approx.)Height: 394 mm; Width: 608 mm; Depth: 191 mm
WeightApprox. 28 kg
Sampling Pipe Connection1/4 inch BSP inlet connection
Exhaust Connection45 mm inside diameter / 48 mm outside diameter
ProtectionMarine engine safety monitoring system
Suitable ApplicationMain propulsion engines, auxiliary engines, marine diesel engines

Frequently Asked Questions

What is the Graviner MK5 Oil Mist Detector?

The Graviner MK5 Oil Mist Detector is a marine engine safety system designed to continuously monitor oil mist concentration inside the crankcase of diesel engines. It provides early warning of abnormal engine conditions, helping reduce the risk of crankcase explosions and serious mechanical failures.

How does the Graviner MK5 work?

The MK5 automatically samples air from each crankcase compartment and passes it through an optical measuring chamber. By measuring changes in light transmission caused by suspended oil mist particles, the system determines oil mist concentration and compares it with preset alarm levels.

Why is oil mist monitoring important?

Abnormal oil mist concentration may indicate:

  • Bearing overheating
  • Lubrication failure
  • Excessive friction
  • Mechanical wear
  • Developing engine faults

Early detection enables engineers to investigate problems before major engine damage occurs.

Which engines use the Graviner MK5?

The Graviner MK5 has been widely installed on:

  • Main Marine Diesel Engines
  • Auxiliary Diesel Engines
  • Offshore Diesel Engines
  • Marine Power Generation Engines
  • Industrial Diesel Engine Applications

Compatibility should always be verified before ordering replacement equipment or spare parts.

Does the MK5 continuously monitor the engine?

Yes.

The system continuously samples crankcase air during engine operation and provides uninterrupted monitoring of oil mist concentration.

What happens when an alarm is activated?

When oil mist density exceeds the programmed alarm threshold, the detector activates visual and audible alarms. Depending on the vessel's automation system, alarm outputs may also be connected to engine monitoring or protection systems.

Does the Graviner MK5 require regular maintenance?

Yes.

Routine inspection of the sampling system, optical measuring chamber, electrical connections, and alarm functions helps maintain reliable system performance.

Is calibration necessary?

Periodic functional testing and calibration verification are recommended in accordance with the manufacturer's maintenance procedures and the vessel's Planned Maintenance System (PMS).

What spare parts are commonly available?

Common replacement components include:

  • Optical Measuring Chamber Parts
  • Light Source Assemblies
  • Photocells
  • Sampling Pumps
  • Sampling Pipes
  • Air Filters
  • Alarm Modules
  • Display Components
  • Power Supply Components
  • Connectors
  • Wiring Assemblies

Availability depends on the equipment version.

Can the MK5 be repaired?

Yes.

Many components can be repaired or replaced using genuine spare parts. Repairs should be carried out by qualified marine engineers or authorized service personnel.

Who typically uses the Graviner MK5?

The system is commonly used by:

  • Chief Engineers
  • Second Engineers
  • Engine Superintendents
  • Technical Managers
  • Marine Service Engineers
  • Shipyards
  • Ship Management Companies
  • Offshore Operators
How do I identify the correct replacement parts?

To help identify compatible parts, provide:

  • Equipment Model Number
  • Serial Number
  • Engine Model
  • Nameplate Photograph
  • Existing Part Number (if available)
Can the MK5 be integrated with vessel alarm systems?

Yes.

The detector can provide alarm outputs for connection to engine alarm and monitoring systems, depending on the vessel's automation configuration.

Why use genuine replacement parts?

Genuine replacement parts help maintain:

  • Reliable monitoring
  • Accurate oil mist detection
  • System compatibility
  • Long equipment service life
  • Safe engine operation
Why is the Graviner MK5 still widely supported?

Although newer models are available, many vessels continue to operate the MK5 due to its proven reliability, durable construction, and long service history. Regular maintenance and genuine spare parts help keep these systems operating effectively.

Direct Marine Supply Desk

Need Graviner MK5 Oil Mist Detector or Spare Parts?

Get in touch with Ship Care Service for immediate commercial pricing, lead times, certificate verification, and Singapore anchorage launch delivery.

Fast 2–4h Technical Quotation 100% Genuine Certified Marine Gear Singapore Launch & Worldwide Dispatch
Chat with us on WhatsApp
Request a Quote