Get a Quote

Graviner MK6 Oil Mist Detector

Brand: Graviner ● In Stock & Ready for Dispatch
Graviner MK6 Oil Mist Detector with addressable detector heads for marine diesel engine crankcase oil mist monitoring.
The Graviner MK6 Oil Mist Detector continuously monitors crankcase oil mist concentration using addressable optical detector heads to improve marine engine safety and reliability.

The Graviner MK6 Oil Mist Detector is an advanced marine engine safety system designed to continuously monitor oil mist concentration inside the crankcase of diesel engines. Developed as the successor to earlier Graviner systems, the MK6 introduced an analogue addressable architecture, individual detector heads, and the elimination of traditional sampling pipes, providing faster detection, simplified installation, and improved system reliability.

Technical Specifications

ParameterSpecification
Product NameOil Mist Detector (OMD)
ManufacturerGraviner (Kidde / Carrier Fire & Security), UK
ModelMK6 Oil Mist Detector
ApplicationMarine diesel engine crankcase oil mist monitoring
PurposeEarly detection of oil mist caused by bearing overheating and prevention of crankcase explosion
Suitable Engines2-stroke and 4-stroke diesel engines
Detection PrincipleOptical sensing using light scatter technology
Measuring MethodDifferential oil mist density measurement
Sampling MethodDirect crankcase-mounted detectors (no sample pipe required)
Detector TypeIndividual electronic detector units mounted on engine crankcase
Detection SensitivityMeasures oil mist density from approximately 0.05 mg/L
System CapacityUp to 64 detectors
Maximum Engines MonitoredUp to 8 engines on one system
Scanning TimeApprox. 1.2 seconds for 64 detectors
Detector CommunicationSerial data communication through engine junction box
Detector Protection RatingIP65
Detector Operating Temperature0°C to 70°C
Detector Power Supply24 VDC system supply
Detector Power ConsumptionApprox. 2.8 W
Detector Dimensions (H × W × L)175 × 90 × 205 mm
Detector WeightApprox. 0.6 kg
Detector IndicatorsGreen: Detector ON; Red: Alarm; Amber: Detector Fault
Junction Box Protection RatingIP65
Junction Box CapacityMaximum 14 detector inputs
Control Panel Protection RatingIP32
Control Panel Power Supply24 VDC (+30% / -25%)
Control Panel Power ConsumptionApprox. 5.2 W
Main Alarm OutputVolt-free change-over contact
Fault Alarm OutputVolt-free change-over contact
Engine Slowdown / Shutdown OutputUp to 8 outputs (one per engine)
Relay Contact Rating30 VDC, 1 A
Average Alarm SettingAdjustable 0.3 mg/L to 1.3 mg/L (default approx. 0.7 mg/L)
Deviation Alarm SettingAdjustable 0.05 mg/L to 0.5 mg/L (default approx. 0.3 mg/L)
Backup Alarm1.6 mg/L fixed
Detector Mounting¾ inch BSP mounting connection
DisplayLCD display with alarm and system status indication
Installation AdvantageNo oil mist sampling pipes required; reduced installation and maintenance work
CertificationsDesigned for marine classification requirements

Frequently Asked Questions

What is the Graviner MK6 Oil Mist Detector?

The Graviner MK6 Oil Mist Detector is an addressable marine engine safety system designed to continuously monitor oil mist concentration inside the crankcase of diesel engines. It provides early warning of abnormal engine conditions, helping reduce the risk of crankcase explosions and costly engine damage.

How is the Graviner MK6 different from the MK5?

The Graviner MK6 uses individual addressable detector heads mounted directly on each crankcase compartment, while the MK5 relies on a centralized sampling system with sampling pipes. The MK6 offers faster fault identification, simplified installation, and reduced maintenance due to its distributed detector design.

Why is oil mist detection important?

Oil mist monitoring helps identify developing engine problems such as:

  • Bearing overheating
  • Lubrication failure
  • Excessive friction
  • Mechanical wear
  • Abnormal crankcase conditions

Early detection allows engineers to investigate and resolve issues before major engine damage occurs.

Which engines use the Graviner MK6?

The Graviner MK6 is commonly installed on:

  • Main Marine Diesel Engines
  • Auxiliary Diesel Engines
  • Marine Generator Engines
  • Offshore Diesel Engines
  • Industrial Diesel Engine Applications

Compatibility should always be confirmed before ordering replacement equipment or spare parts.

How does the MK6 detect oil mist?

Each crankcase compartment is equipped with an optical detector head that continuously measures oil mist concentration using the light-scatter principle. Measurement data is transmitted digitally to the central control unit for continuous monitoring and alarm management.

What happens when an alarm is activated?

If oil mist concentration exceeds the programmed alarm threshold, the control unit immediately activates visual and audible alarms while identifying the affected detector location. Depending on the vessel's automation system, alarm outputs may also be transmitted to engine monitoring or protection systems.

Does the Graviner MK6 require routine maintenance?

Yes.

Routine inspection of detector heads, electrical connections, controller operation, and alarm functions helps maintain reliable long-term performance.

Is calibration required?

Periodic functional testing and calibration verification are recommended according to the manufacturer's maintenance procedures and the vessel's Planned Maintenance System (PMS).

What spare parts are commonly available?

Common replacement components include:

  • Addressable Detector Heads
  • Optical Sensor Assemblies
  • Control Unit Components
  • Communication Modules
  • Wiring Harnesses
  • Alarm Modules
  • Display Components
  • Power Supply Components
  • Connectors
  • Mounting Accessories

Availability depends on the equipment version.

Can individual detector heads be replaced?

Yes.

One advantage of the MK6 system is its modular design, allowing individual detector heads to be replaced independently without replacing the complete monitoring system, provided the replacement component is compatible with the installed equipment.

Who typically operates the Graviner MK6?

Typical users include:

  • Chief Engineers
  • Second Engineers
  • Marine Engineers
  • Engine Superintendents
  • Technical Managers
  • Shipyards
  • Ship Management Companies
  • Offshore Maintenance Teams
How can I identify the correct replacement parts?

Providing the following information helps ensure compatibility:

  • Equipment Model
  • Serial Number
  • Engine Model
  • Equipment Nameplate
  • Existing Part Number (if available)
Can the MK6 integrate with engine alarm systems?

Yes.

The control unit can provide alarm outputs for integration with engine monitoring systems, alarm management systems (AMS), and other vessel automation systems, depending on the installation configuration.

Why should I choose genuine replacement parts?

Using genuine replacement parts helps maintain:

  • Reliable oil mist detection
  • System compatibility
  • Long equipment life
  • Accurate monitoring
  • Safe engine operation
Why is the Graviner MK6 widely used?

The Graviner MK6 has earned a strong reputation in the marine industry because of its:

  • Addressable detector technology
  • Optical light-scatter detection
  • Continuous crankcase monitoring
  • Fast fault identification
  • Simplified maintenance
  • Reliable marine performance
  • Modular design
Direct Marine Supply Desk

Need Graviner MK6 Oil Mist Detector or Spare Parts?

Get in touch with Ship Care Service for immediate commercial pricing, lead times, certificate verification, and Singapore anchorage launch delivery.

Fast 2–4h Technical Quotation 100% Genuine Certified Marine Gear Singapore Launch & Worldwide Dispatch
Chat with us on WhatsApp
Request a Quote