Riken Keiki GX-9000 Portable Multi Gas Detector

Brand: Riken Keiki ● In Stock & Ready for Dispatch
The Riken Keiki GX-9000 is a portable multi gas detector with an internal sampling pump, Bluetooth connectivity, and support for monitoring up to six gases in marine, offshore, industrial, and confined-space applications.

The Riken Keiki GX-9000 Portable Multi Gas Detector is a premium pump-operated multi-gas detector designed for advanced gas monitoring in hazardous industrial, marine, offshore, and confined-space environments. Capable of simultaneously detecting up to six gases, the GX-9000 combines a powerful internal sampling pump with multiple sensor technologies, including catalytic, infrared, electrochemical, thermal conductivity, and PID sensors. Its rugged IP66/IP68-rated construction, Bluetooth® connectivity, long battery life, and explosion-proof design make it one of the most versatile portable gas detectors for safety-critical applications.

Technical Specifications

SpecificationDetails
Product NameRiken Keiki GX-9000 Portable Multi Gas Detector
BrandRiken Keiki
ModelGX-9000
Product TypePortable Pumped Multi-Gas Detector
Gas Detection CapacityUp to 6 gases simultaneously
Standard Gas ConfigurationOxygen (O₂), Carbon Monoxide (CO), Hydrogen Sulfide (H₂S), Combustible Gas (LEL) + optional additional gases
Additional Detectable GasesVOCs, CO₂, NH₃, Cl₂, SO₂, HCl, HCN, O₃, H₂, CH₄, i-C₄H₁₀, and other gases depending on sensor configuration
Sampling MethodInternal suction pump / dual sampling type
Pump PerformanceHigh-performance built-in pump for remote sampling applications
Maximum Sampling Tube LengthUp to approximately 45 m (application dependent)
Sensor TechnologyNew Ceramic Catalytic Method, Thermal Conductivity Method, Non-Dispersive Infrared (NDIR), Potentiostatic Electrolysis, Photo-Ionization Detector (PID)
Detection RangeDepends on selected gas sensor configuration
DisplayLarge LCD display with gas concentration, alarm status, battery status, and operating information
Alarm TypesGas alarm and fault alarm
Alarm IndicatorsFlashing LED lamp, buzzer alarm, flashing gas concentration display
Alarm FunctionsLow, High, STEL, TWA, Over Range, Pump Failure, Sensor Error, Battery Warning
Data ManagementBluetooth Low Energy (BLE) communication for smartphone data management
Mobile ConnectivityCompatible with Riken data management application (RK Link)
CalibrationGas calibration supported using standard calibration gases
Battery TypeRechargeable Lithium-ion battery unit (BUL-9000) or AA alkaline battery unit (BUD-9000)
Battery Runtime (Li-ion Battery)Approx. 25 hours (fully charged, GX-9000 standard configuration)
Battery Runtime (Dry Battery)Approx. 12 hours (25°C, no alarm, no lighting)
Operating TemperatureContinuous: -20°C to +50°C; Temporary: -40°C to +60°C (sensor dependent)
Operating HumidityContinuous: 10–90% RH (non-condensing); Temporary: 0–95% RH (non-condensing)
Operating Pressure Range80–120 kPa
Ingress Protection RatingIP66/IP68 equivalent
Drop Resistance1.5 m drop durability
Explosion ProtectionFlameproof enclosure + intrinsic safety
ATEX CertificationII 1G Ex da ia IIC T4 Ga / II 1G Ex ia IIC T4 Ga (configuration dependent)
IECEx CertificationEx da ia IIC T4 Ga / Ex ia IIC T4 Ga
Other ApprovalsJapan Ex, IECEx, ATEX, MED, JIS, UK-MER (depending on configuration)
CE ComplianceEMC, ATEX, RoHS, Radio Equipment compliance
DimensionsApprox. 158 (W) × 85 (H) × 132 (D) mm (excluding projections)
WeightApprox. 1.1 kg (including battery and battery unit)
Sensor WarrantyUp to 3 years (depending on sensor type)
Housing DesignRugged industrial enclosure for harsh environments
ApplicationsOil & Gas, Petrochemical, Marine, Confined Space Entry, Chemical Plants, Mining, Wastewater Treatment, Industrial Safety

Frequently Asked Questions

What is the standard delivery lead time for Riken Keiki GX-9000 Portable Multi Gas Detector?
For standard stocked units, we provide same-day or next-day launch delivery to Singapore anchorages, Jurong port, and shipyards. For international vessels, we dispatch worldwide via DHL/FedEx Express air freight with 2 to 4 business days delivery.
Does this equipment include calibration certificates?
Yes. All portable and fixed detectors, UTI meters, and monitoring instruments supplied or calibrated by Ship Care Service include manufacturer inspection reports and traceable international calibration test certificates.
Are genuine spare parts and replacement sensors available for this model?
Yes, we maintain an extensive inventory of original manufacturer sensors, PCB motherboards, sampling pumps, filters, and sealing kits specifically for Riken Keiki.
How can I request a commercial quotation?
Simply fill out the Request a Quote form on the right or click "Chat on WhatsApp". Our marine sales engineering desk provides firm commercial quotes with lead times within 2 to 4 hours.
Direct Marine Supply Desk

Need Riken Keiki GX-9000 Portable Multi Gas Detector or Spare Parts?

Get in touch with Ship Care Service for immediate commercial pricing, lead times, certificate verification, and Singapore anchorage launch delivery.

Fast 2–4h Technical Quotation 100% Genuine Certified Marine Gear Singapore Launch & Worldwide Dispatch
Chat with us on WhatsApp
Request a Quote